Ducted heat pump PEA-RP-GA (air conditioner)

Ducted heat pump PEA-RP-GA (air conditioner)

High power PEA series indoor equipment used along with outdoor units Power Inverter (PUHZ-RP200/250YKA, PUHZ-ZRP200/250YKA) and Standart Inverter (PUHZ-P200/250YHA).

Category: .
Save PDF: This page as PDF Share Us:
Certificates and markings
R410A

High power PEA series indoor equipment used along with outdoor units Power Inverter (PUHZ-RP200/250YKA, PUHZ-ZRP200/250YKA) and Standart Inverter (PUHZ-P200/250YHA).

HIGH STATIC PRESSURE FAN

Flexible channel design and high outside static pressure of 150Pa. Enhanced airflow variations ensure optimum operation to meet the requirements of the layout of premises.

LONG REFRIGERANT PIPING

The piping may be up to 100 m long (if equipped with Power Inverter outdoor units) and up to 70 m long (with Standart Inverter outdoor units). This allows for optimum layout of the indoor equipment in premises.

INDOOR UNIT POWER – 20 TO 50 KW

A wide choice of equipment, adapting to the size and layout of the buildings.

PAR-31MAA INTEGRATED CONTROL

PAR-31MAA remote controller may control up to 16 systems* so it is an ideal solution for integrated control of the entire conditioning system of a building.

 

*the system is considered to include: indoor unit (PEA-RP200/250GA) connected to an outdoor installation; PEA-RP400/500GA connected to 2 outdoor units shall be considered as 2 systems.

Indoor unit model PEA RP200GA PEA RP250GA PEA RP400GA PEA RP500GA
Weight (kg) 70 77 130 133
Dimensions (mm)
Depth 634 634 764 764
Width 1400 1600 1947 1947
Height 400 400 595 595
Airflow (m3/h) 3120-3900 3840-4800 7200 9600
Level of noise (dB) 48-51 49-52 52 53

Operating current (A) inner/outer

2.0/19.0 2.3/21.0 3.8/19.0(x2) 5.4/21.0(x2)
Power supply        inner/outer – 400 V/3 phase/50Hz /400 V/3 phase/50Hz
Recommended fuse (A)      inner/outer – 15 /32 

 

Indoor unit model PEA RP200GA PEA RP250GA PEA RP400GA PEA RP500GA
Outdoor unit model PUHZ-(Z)RP200YKA PUHZ-(Z)RP250YKA 2xPUHZ-(Z)RP200YKA 2xPUHZ-(Z)RP250YKA
PUHZ-ZRP Standard inverter
Cooling (kW) 19.0
(9.0-22.4)
22.0
(11.2-27.0)
38.0
(18.0-44.8)
44.0
(22.4-54.0)
EER 2.94 2.65 3.05 2.57
Heating (kW) 22.4
(9.5-25.0)
27.0
(12.5-31.0)
44.8
(18.0-50.0)
54.0
(25.0-62.0)
COP 3.23 3.02 3.34 2.94
PUHZ-P Standard inverter 
Cooling (kW) 19.0
(9.0-22.4)
22.0
(11.2-27.0)
38.0
(18.0-44.8)
44.0
(22.4-54.0)
EER 2.86 2.53 2.96 2.46
Heating (kW) 22.4
(9.5-25.0)
27.0
(12.5-31.0)
44.8
(18.0-50.0)
54.0
(25.0-62.0)
COP 3.15 2.90 3.26 2.83

More detailed technical characteristics of outdoor units are available in the section Outdoor Units of Air Conditioners/Heat Pumps, or if you just click on the name of an appropriate outdoor unit model in the first column of the table Power Combinations of Outdoor Units.