Multi Split MXZ series heat pumps (air conditioners)

5ce61b52892c79136df150b841f94014
95e76538dba32f266dc502d0c1e2f36d
0939a0ff6e02a7700c2f6fccebb5f7d4
3113eafce23f5da2818788a9f61998a5
56378312424627d38b866d6f697c1e47

Multi Split MXZ series heat pumps (air conditioners)

From €2,800.00 tax excl.

The Multi Split System can consist of a few indoor units connected to one outdoor unit, therefore, heating (or cooling) of all the desired premises is simple and efficient.

Add to cart
Save PDF: This page as PDF Share Us:
Certificates and markings
R410A 5 metų garantija

Up to eight indoor units connected to one outdoor unit!

The Multi Split System can consist of a few indoor units connected to one outdoor unit, therefore, heating (or cooling) of all the desired premises is simple and efficient. Depending on the model of a heat pump, it is possible to connect from 2 to 8 indoor sections to the outdoor section (see a table of technical specifications).

It is up to you to choose what temperature should be in bedrooms, the kitchen or the living room. The Multi Split System allows you to choose freely what indoor units you prefer to connect: wall-mounted, floor, ceiling, cassette or the ones installed into air channels. Everything has been created for your best comfort.

New product! The new MXZ-2E53VAHZ heat pump (air conditioner) with the installed patented HYPER HEATING Technology is already available! This technology ensures the retention of the constant nominal heating power (6.4kW) down to -15℃, and the guaranteed cost-efficient heat supply even down to -25℃. This heat pump can be connected to two indoor units of the desired type and model (wall-mounted, cassette, ceiling or ducted) – thus you will be able to particularly efficiently heat different floors of a house or different rooms even on the coldest winter days. In the summer, appliances will operate as air conditioners by efficiently cooling the premises.

 

Example

 Multi_Split_sistema

Number of supported indoor units up to 2 indoor units up to 2 indoor units
up to 2 indoor units up to 2 indoor units up to 3 indoor units
Model MXZ-2D33VA MXZ-2D40VA MXZ-2D53VAH

MXZ-2E53VAHZ

New product!

MXZ-3D54VA
Cooling power (kW) 3.3 (1.1-3.8) 4.0 (1.1-4.3) 5,3 (1,1-5,6) 5,3 (1,1-6.0) 5.4 (1.9-6.8)
SEER/Energy class 5,5/A 5,7/A+ 7,1/A++ 6.5/A++ 5,8/A+
Heating power (kW) 4.0 (1.0-4.1) 4.5 (1.0-4.8) 6,4 (1,0-7,0) 6,4 (1,0-7,0) 7.0 (2.6-9.6)
SCOP/Energy class 4,1/A+ 4,1/A+ 4,1 /A+ 4,1 /A+ 3,9/A
Airflow (m3/min) cooling/heating 32.9-33.7 29.2-27.7 32.9-33.3 47.0-47.0 42.1-43.0
Level of noise (dB(A)) cooling/heating 49-50 49-50 50-53 45-47 50-53
Guaranteed heating up to (°C) -15/-20* -15/-20* -20

HYPER HEATING technology

-25!

(up to -15 ° C to kept constant heat output 6,4 kW)

-15/-20*
Weight (kg) 32 34 38 61 57
Dimensions (mm) 550 x 800(+69) x 285(+59,5) 550 x 800(+69) x 285(+59,5) 550 x 800(+69) x 285(+59,5)  796 x 950 x 330 710 x 840(+30) x 330(+66)
Power supply voltage 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50

Maximum operating current (A)

10,0 12,2 12,2 15,6 18,0
Recommended fuse (A) 10 15 15 16 20
Pipe bores (gas/liquid)

2 x 3/8”

2 x 1/4”

2 x 3/8”

2 x 1/4”

2 x 3/8”

2 x 1/4”

2 x 3/8”

2 x 1/4”

3 x 3/8”

3 x 1/4”

Maximum pipe length (m) 20 30 30  30 50
Maximum height difference (m)** 15 (10) 15 (10) 15 (10)  15 (10) 15 (10)

 

Number of supported indoor units up to 4 indoor units up to 4 indoor units up to 5 indoor units up to 8 indoor units* up to 8 indoor units*
Model MXZ-4D72VA MXZ-4D83VA MXZ-5D102VA PUMY-P125YKM1 PUMY-P140YKM1
Cooling power (kW) 7.2 (3.7-8.8) 8.3 (3.7-9.2) 10.2 (3.9-11.0) 14.0 15.5
SEER/Energy class 5.7/A+ 5.2/A 5.3/A EER-4.05 EER-3.43
Heating power (kW) 8.6 (3.4-10.7) 9.0 (3.4-11.6) 10.5 (4.1-14.0) 16.0 18,0
SCOP/Energy class 3.9/A 3.9/A 3.8/A COP-4.28 COP-4.03
Airflow (m3/min) cooling/heating 42.1-43.0 42.1-43.8 56.6-59.3 110.0-110.0 110.0-110.0
Level of noise (dB(A)) 49-53 49-50 53-55 50-52 51-53
Guaranteed heating up to (°C) -15/-20* -15/-20* -15/-20* -20 -20
Weight (kg) 58 69 70 125 125
Dimensions (mm) 710 x 840(+30) x 330(+66) 710 x 840(+30) x 330(+66) 900 x 900 x 320(+67) 1338 x 1050 x 330(+25) 1338 x 1050 x 330(+25)
Power supply voltage 230/1/50 230/1/50 230/1/50 400/3/50 400/3/50

Maximum operating current (A)

18,0 20,4 21,4 13,0 13,0
Recommended fuse (A) 20 25 25 25 25
Pipe bores (gas/liquid); 1 x 1/2”

3 x 3/8”

4 x 1/4”

1 x 1/2”

3 x 3/8”

4 x 1/4”

1 x 1/2”

4 x 3/8”

5 x 1/4”

1 x 5/8”

1 x 3/8”

1 x 5/8”

1 x 3/8”

Maximum pipe length (m) 60 70 80 It depends on combination of models of internal devices It depends on combination of models of internal devices
Maximum height difference (m)** 15 (10) 15 (10) 15 (10) It depends on combination of models of internal devices It depends on combination of models of internal devices

* In addition, the installation of the cable glow MAC AUTO3-1,5 guaranteed economical heating to -20C outside temperature

** If the outdoor unit is installed above the indoor unit, the height difference decreases to 10 m

 

Connecting the RAC series devices to the internal PUMY-125 / 140YKM1 blocks required for Branch Box) and distributor:

  • PACMK30BC hub will max connection of 3 indoor units,

  • PAC-MK50BC hub will max connection of 5 indoor units,

  • MSDD-50AR-E distributor (connecting by nuts) or MSDD50BR-E distributor (connecting by soldering).

 

Distances and height difference requirements of pipes- are in the documents.

 

[uždaryti]