R410A
Model PUHZ-ZRP35VKA PUHZ-ZRP50VKA PUHZ-ZRP60VHA PUHZ-ZRP71VHA
Cooling
Nominal power (kW) 3.5 (1.6-4.5) 5.0 (2.3-5.6) 6.1 (2.7-6.5) 7.1 (3.3-8.1)
SEER* 6.5 5.6 5.7 6.4
Energy class A++ A+ A+ A++
Heating
Nominal power (kW) 4.1 (1.6-5.2) 6.0 (2.5-7.3) 7.0 (2.8-8.2) 8.0 (3.5-10.2)
Heat quantity kW when the outside temp. -10oC  2.3  3.8  4.4  4.7
Heat quantity kW when the outside temp. -20oC  2.2. (with -11oC outside temp)  3.7 (with -11oC outside temp)  2.8  3.5
SCOP*  4.3  4.1  3.9  4.3
Energy class  A+  A+  A  A+
Dimensions (mm) 630 x 809 x 300(+23) 630 x 809 x 300(+23) 943 x 950 x 330(+30) 943 x 950 x 330(+30)
Weight (kg) 43 46 67 67
Level of noise (dB(A)) for heating/cooling 46/44 46/44 48/47 48/47
Airflow (m3/h)  2700  2700  3300 3300
Power supply voltage (V/phase/Hz) 230/1/50 230/1/50 230/1/50 230/1/50
Maximum operating current (A) 13.0 13.0 19.0 19.0
Recommended fuse (A) 16 16 25 25
Maximum pipe length (m) 50 50 50 50
Maximum height difference of pipes between indoor-outdoor units (m) 30 30 30 30
Pipe bores (gas/liquid) 1/4″…1/2″ 1/4″…1/2″ 3/8″…5/8″ 3/8″…5/8″

Temperature range for guaranteed cost-efficient operation (℃): 

Heating -11~+21 -11~+21  -20~+21  -20~+21
Cooling** -15~+46 -15~+46 -15~+46 -15~+46

 

Model PUHZ-ZRP100YKA PUHZ-ZRP125YKA PUHZ-ZRP140YHA
Cooling
Nominal power (kW) 9.5 (4.9-11.4) 12.5 (5.5-14.0) 13.4 (6.2-15.0)
SEER* 6.4 4.9 5.5
Energy class A++
Heating
Nominal power (kW) 11.2 (4.5-14.0) 14.0 (5.0-16.0) 16.0 (5.7-18.0)
Heat quantity kW when the outside temp. -10oC 7.8 9.3 10.6
Heat quantity kW when the outside temp. -20oC 5.8 7.0 7.9
SCOP* 4.3 3.9 4.0
Energy class A+
Dimensions (mm) 1338 x 1050 x 330(+40) 1338 x 1050 x 330(+40) 1338 x 1050 x 330(+40)
Weight (kg) 123 125 131
Power supply voltage (V/phase/Hz) 51/49 52/50 52/50
Airflow (m3/h) 6600 7200 7200
Power supply voltage (V/phase/Hz) 400/3/50 400/3/50 400/3/50
Maximum operating current (A) 8.0 9.5 13.0
Recommended fuse (A) 16 16 16
Maximum pipe length (m) 75 75 75
Maximum height difference of pipes between indoor-outdoor units (m) 30 30 30
Pipe bores (gas/liquid) 3/8″…5/8″ 3/8″…5/8″ 3/8″…5/8″

Temperature range for guaranteed cost-efficient operation (℃): 

Heating

-20~+21

-20~+21

-20~+21

Cooling** -15~+46 -15~+46 -15~+46

 

Model PUHZ-ZRP200YKA PUHZ-ZRP250YKA
Cooling
Nominal power (kW) 19.0 (9.0-22.4) 22.0 (11.2-27.0)
EER 2.94 2.65
Heating
Nominal power (kW) 22.4 (9.5-25.0) 27.0 (12.5-31.0)
COP 3.23 3.02
Dimensions (mm) 1338 x 1050 x 330(+40) 1338 x 1050 x 330(+40)
Weight (kg) 135 135
Level of noise (dB(A)) 59-62 59-62
Airflow (m3/h) 8400  8400
Power supply voltage (V/phase/Hz) 400/3/50 400/3/50
Maximum operating current (A) 19.0 21.0
Recommended fuse (A) 32 32
Maximum pipe length (m) 100 100
Maximum height difference of pipes between indoor-outdoor units (m) 30 30
Pipe bores (gas/liquid) 3/8″…1″  1/2″…1″

Temperature range for guaranteed cost-efficient operation (℃): 

Heating

-20~+15

-20~+15

Cooling** -15~+46 -15~+46

Note. Heating, cooling power (kW) and performance ratios differ depending on the chosen air-to-air system of the indoor unit (the values in the tables completing the PLA-RP-BA series indoor unit (PUHZZRP35-140) and PEA-RP-GA (PUHZ- ZRP200 / 250)).

*Seasonal coefficients of performance.

**For cooling, when the ambient temperature is lower than -5°C, outdoor units require specific accessories – guards (sold separately)

 

 

Additional accessories:

PAC-SJ06AG-E-S (Protection for cooling up to -15oC). For PUHZ-ZRP35/50VKA models (1 pc.)

PAC-SH63AG-E-S (Protection for cooling up to -15oC). For PUHZ-ZRP60/71VHA models (required 2 pc.)

PAC-SH95AG-E-S (Protection for cooling up to-15oC). For PUHZ-ZRP100-140YHA models (required 2 pc.)

PAC-SH95AG-E-S2 (Protection for cooling up to -15oC). For PUHZ-ZRP200/250YHA models (required 2 pc.)

MSDD-50TR-E (splitter for two internal devices 50:50). For PUHZ-ZRP71-140 models

MSDD-50WR-E (splitter for two internal devices 50:50). For PUHZ-ZRP200/250 models

MSDT-111R-E (splitter for three internal devices 33:33:33). For PUHZ-ZRP140-250 models

MSDF-1111R-E (splitter for four internal devices 25:25:25:25). For PUHZ-ZRP200/250 models

[uždaryti]