Split Power Inverter ZUBADAN PUHZ-SHW112 series heat pump, heating down to -28℃ outdoor temp!

Split Power Inverter ZUBADAN PUHZ-SHW112 series heat pump, heating down to -28℃ outdoor temp!

New PUHZ-SHW series heat pumps with the patented Zubadan technology. The most advanced technologies for cost-efficient and effective heating and cooling.

Category: .
Save PDF: This page as PDF Share Us:
Certificates and markings
R410A

New PUHZ-SHW series heat pumps with the patented Zubadan technology.

The most advanced technologies for cost-efficient and effective heating and cooling.

Due to the installed most advanced technologies and a high-performance compressor, new PUHZ-SHW series appliances have significantly better technical characteristics than their predecessors, PUHZ-HRP series devices. PUHZ-SHW series heat pumps are leaders in the market according to seasonal performance indicators and the released amount of heat under especially low ambient temperatures.

These appliances are intended for heating, preparation of domestic hot water and cooling. Differently from all the other, traditional heat pumps in the market, MITSUBISHI ELECTRIC appliances with the patented ZUBADAN technology maintain stable nominal heating capacity even down to -15℃ outdoor temperature, while the manufacturer guarantees cost-efficient heat supply down to -28℃ outdoor temperature.

Outdoor units of PUHZ-SHW heat pumps may be matched with indoor units of both the air-to-air system and air-to-water system.

In order to ensure safe operation of a heat pump in extreme outdoor air conditions, MITSUBISHI ELECTRIC recommends using wind/snow guards. These are special covers which protect the outdoor unit of a heat pump from cold winds, snow and hail as well as enable the reduction of the duration of auto-defrost of an appliance and extension of the operation time between auto-defrost cycles. This reduces electric power consumption and ensures a smoother and longer service of a heat pump.

 

 

 

 
Model PUHZ-SHW112YHA
Cooling
Nom. power (kW)1 10.00 (3.40-11.17)
EER1 2.83
Heating
Nom. power (kW)2 11.20 (5.53-14.82)
COP2 4.46
Heat points kW when the outside temp +7oC3 14.82
Heat points kW when the outside temp +2oC3 13.46
Heat points kW when the outside temp -7oC3 14.91
Heat points kW when the outside temp -15oC3 13.59
Heat points kW when the outside temp -20oC3 10.46
Dimensions (mm) 1350x950x330(+30)
Weight (Kg) 134
Level of noise, dB(A) (heating/cooling) 52/51
Airflow, m3/h. 6000
Power supply voltage (V/phase/Hz) 400/3/50
Maximum operating current (A) 13.0
Recommended fuse (A) 16
Max pipe length (m) 75
Maximum height difference between indoor and outdoor units (m) 30
Pipe bores (gas/liquid) 3/8″…5/8″
Prepare a water temp., oC (max. Heating / min. Cooling) +60/+5
Temperature range for guaranteed cost-efficient operation (℃) 
Heating

-28~+21

BKV4 -28~+35
Cooling -155~+46

1 ambient temperature is +35oC, outgoing water temperature is +7oC.

2 ambient temperature is +7oC, outgoing water temperature is +35oC.

3 outgoing water temperature is +35oC.

4 domestic hot water

5 While cooling, when ambient temperature is lower than -5℃, outdoor units need a special accessory – guards (sold separately)

 