Standard Inverter PUHZ P100-250 series heat pumps (air conditioners)

Standard Inverter PUHZ P100-250 series heat pumps (air conditioners)

Category: .
Save PDF: This page as PDF Share Us:
Certificates and markings
R410A
Model PUHZ-P100YHA PUHZ-P125YHA PUHZ-P140YHA
Cooling power (kW) 9.4 (4.9-11.2) 12.3 (5.5-14.0) 13.6 (5.5-15.0)
SEER* 5.2 EER-3.01 EER – 2.61
Energy class A B D
Heating power (kW) 11.2 (4.5-12.5) 14.0 (5.0-16.0) 16.0 (5.0-18.0)
SCOP* 3.8 COP-3.41 COP-3.21
Energy class A B C
Airflow (m3/h) 3600 6000 6000
Level of noise (dB(A)) 50-54 51-55 52-56
Maximum pipe length (m) 50 50 50
Maximum height difference (m) 30 30 30
Maximum internat units 2 2 3
Weight (kg) 77 101 101
Dimensions (mm) 943 x 950 x 330 (+30) 1350 x 950 x330 (+30) 1350 x 950 x330 (+30)
Power supply voltage (V/phase/Hz) 400/3/50 400/3/50 400/3/50
Recommended fuse (A) 16 16 16
Pipe bores (mm) 3/8″…5/8″ 3/8″…5/8″ 3/8″…5/8″

Temperature range for guaranteed cost-efficient operation (℃): 

Cooling** -15~+46 -15~+46 -15~+46
Heating -15~+21 -15~+21 -15~+21

Power (kW) and performance ratios may differ depending on the chosen internal units (the values in the tables completing with PLA-RP-BA models)

*Seasonal coefficients of performance.

**For cooling, when the ambient temperature is lower than -5°C, outdoor units require specific accessories – guards (sold separately)

 

Model PUHZ-P200YKA PUHZ-P250YKA
Cooling power (kW) 19.0 (9.0-22.4) 22.0 (11.2-27.0)
EER 2.86 2.53
Energy class
Heating power (kW) 22.4 (9.5-25.0) 27.0 (12.5-31.0)
COP 3.15 2.90
Energy class
Airflow (m3/h) 7800 7800
Level of noise (dB(A)) 58-60 59-62
Maximum pipe length (m) 70  70
Maximum height difference (m) 30  30
Maximum internat units 4  4
Weight (kg) 127 135
Dimensions (mm) 1338 x 1050 x 330 (+40) 1338 x 1050 x 330 (+40)
Power supply voltage (V/phase/Hz) 400/3/50 400/3/50
Recommended fuse (A) 32 32
Pipe bores (mm) 3/8″…1″ 1/2″…1″

Temperature range for guaranteed cost-efficient operation (℃): 

Cooling* -15~+46 -15~+46
Heating -20~+21 -20~+21

Power and performance ratios may differ depending on the chosen internal units (the values in the tables completing with PEA-RP-GAQ models)

*For cooling, when the ambient temperature is lower than -5°C, outdoor units require specific accessories – guards (sold separately)

 

Additional accessories:

PAC-SJ06AG-E-S (Protection for cooling up to -15oC). 1 pc. PUHZ-P100YHA, 2 pc.- PUHZ-P125/140YHA

PAC-SH95AG-E-S2 (Protection for cooling up to -15oC). 2 pc. PUHZ-P200/250YHA

MSDD-50TR-E (splitter for two internal devices 50:50). PUHZ-P100-140YHA

MSDD-50WR-E (splitter for two internal devices 50:50). PUHZ-P200/250YKA

MSDT-111R-E (splitter for three internal devices 33:33:33). PUHZ-P140/200/250YH(K)A

MSDF-1111R-E (splitter for four internal devices 25:25:25:25). PUHZ-P200/250YKA